STATIX Free calculators
Learn › Steel Design 2 › Lesson 1
Course · lesson 1 of 6

The portal frame building

How a single-storey steel building stands up: the frames, purlins, girts and bracing, the layout that sets them, and the paths that carry gravity and wind to the ground. The rest of the course designs each part with a STATIX calculator.

1. Learning outcomes

After this lesson you can:

  • name the parts of a portal frame building and say what each one carries;
  • set out a layout: span, bay, eaves height and pitch;
  • follow the gravity and wind load paths to the bases;
  • place the bracing, and find the force in a wall brace;
  • pick the combinations that govern a light roof, including uplift.

2. Before you start

3. The building

frames at a regular spacingwall bracing (end bay)roof bracing (end bay), purlins, girts, struts
A portal frame building: rigid frames across the span at a regular spacing, purlins on the rafters and girts on the columns to carry the sheeting, and bracing in the roof and walls to carry loads along the building. The end frames (gable frames) are often lighter, with gable posts.
spaneavespitchbay =framespacing
Layout. The span, the eaves height, the roof pitch and the bay (the frame spacing) set almost everything else: the frame moments, the purlin and girt spans, and the sheeting. The STATIX showcase frame is an 18 m span with 6 m bays, 6 m eaves and a 10° roof; the course follows Loads 1’s 20 m warehouse.

4. Load paths

sheetingkPapurlinskN/mraftersframecolumnsN, M, Vbasesfootingeach element carries its share to the nextline load on a frame = kPa × frame spacing
The gravity load path. The roof load goes from the sheeting to the purlins, from the purlins to the rafters as point loads close enough to treat as a line load (the pressure times the frame spacing), round the frame to the columns, and down to the bases and footings.
girtsuplift on the roofthe frame bends in its own plane: rigid eaves
Wind across the building. The girts take the wall pressure to the columns, the purlins take the roof suction to the rafters, and the frame resists both by bending in its own plane through its rigid eaves (and apex) joints. On a light roof the suction is larger than the weight: the frame and its bases go into uplift.
eaves struts along the buildingplan: gable wind → gable posts → roof girder → wall bracing
Wind on the gable. The frames cannot resist load along the building, so the gable posts pass the wind to a horizontal roof girder (the roof bracing in the end bay), the eaves struts carry it along the eaves, and the wall bracing takes it down to the bases. Every frame relies on that system for its stability out of plane.

5. Bracing and restraint

X (tension only)Kportalan X brace in tension only: one diagonal works each way
Wall bracing. Crossed flats, rods or angles working in tension only are the lightest; a K-brace leaves room for a door; a portal (a stiff frame in the bay) keeps the bay open. Brace at least one bay in each wall line, usually the end bays or one near the middle.
hogging atthe eavessagging near the apexpinned bases: no moment at the foot; fixed bases: a moment there too
Frame action under gravity. The rigid eaves joints make the rafters and columns work together: the largest moments are at the eaves (the haunch is there to carry them), with a smaller sagging moment near the apex. Most portal frames have pinned bases, so the columns carry no moment at the foot, and the footings stay small.
purlin on the top flangefly brace tothe inner flangenear the eaves the inner(bottom) flange is incompression; purlins holdonly the top flange
Restraint. Purlins and girts hold the outer flange of rafters and columns, but under gravity near the eaves (and under uplift along the rafter) the inner flange is in compression. Fly braces from purlins or girts to the inner flange restrain it; Steel Design 1 lesson 3 explains the lateral-torsional buckling they prevent.

6. The combinations

1.2 G + 1.6 Qgravity: most moment at the eaves1.35 G + 1.0 QSTR-P: rarely governs a light roof0.9 G + 1.6 Wuplift: inner flange, bases in tension1.2 G + 1.6 W + ...side wind with gravity
The combinations that govern a light steel roof (SANS 10160-1, Loads 1 lesson 1). Gravity with the imposed roof load sizes the eaves; the uplift case with the permanent load taken low (0.9 G) reverses the moments, puts the inner flange in compression along the rafter and lifts the bases. Both internal pressure cases go to the frame (Loads 1 lesson 5).
Cpi +0.2: more upliftCpi −0.3: more wall load
Two internal pressure cases. Positive internal pressure adds to the roof suction (the uplift case); negative internal pressure adds to the windward wall load and eases the uplift. Each governs different members, so the frame is analysed for both.

7. The course

1 the buildingloads, bracing2 purlins, girtscold-formed purlin3 cold-formedcold-formed member4 rafters, columnssteel member5 eaves haunchhaunch calculator6 apex, baseapex, base plate
The course: one building from layout to the last joint, each lesson tied to a STATIX calculator. It builds on Steel Design 1 (members, bolts, welds and base plates) and Loads 1 (combinations and wind).

8. Example A: gravity and uplift on an interior frame

The worked parts open with a university or college email, a student licence (statix.engineering/university/), a calculator pack or a paid plan. Sign in to open them.

9. Example B: wind along the building

The worked parts open with a university or college email, a student licence (statix.engineering/university/), a calculator pack or a paid plan. Sign in to open them.

10. Do it in STATIX

The worked parts open with a university or college email, a student licence (statix.engineering/university/), a calculator pack or a paid plan. Sign in to open them.

11. Common mistakes

The worked parts open with a university or college email, a student licence (statix.engineering/university/), a calculator pack or a paid plan. Sign in to open them.

12. Exercises

The worked parts open with a university or college email, a student licence (statix.engineering/university/), a calculator pack or a paid plan. Sign in to open them.

13. Self-check quiz

The worked parts open with a university or college email, a student licence (statix.engineering/university/), a calculator pack or a paid plan. Sign in to open them.

14. Lesson 1 on one page

The worked parts open with a university or college email, a student licence (statix.engineering/university/), a calculator pack or a paid plan. Sign in to open them.

Next: Lesson 2, purlins and girtsCold-formed lipped channels on the roof and walls, with the cold-formed purlin calculator.
Go to lesson 2

A worked example for learning, not a design. Check every value against the current code and your own project, and have the design checked and signed by a registered professional engineer.

Early access

Be first to use STATIX 3D and STATIX 2D.

Leave your email and we will tell you when each part is ready for testing. One confirmation now, one message then. A short monthly update only if you tick the box.