STATIX Free calculators
Learn › RC Design 2 › Lesson 2
Course · lesson 2 of 7

Post-tensioned slabs

How an unbonded post-tensioned flat slab strip is designed with the STATIX PT slab calculator on its SANS 10100-1 + ACI 318-19 route: the tendon profile and load balancing, losses, transfer and service stresses, ultimate bending, punching with prestress and deflection.

1. Learning outcomes

After this lesson you can:

  • lay out a tendon profile and find the balanced load;
  • follow the losses from the jacking force to the effective prestress;
  • check the stresses at transfer and in service;
  • check ultimate bending with unbonded tendons and the bonded bars;
  • check punching with prestress and the deflection, and say which code each check comes from.

2. Before you start

3. The idea

a draped tendon pushes the slab up where it sagsand holds part of the weight: load balancing
Why post-tension a slab. A tendon draped low in the spans and high over the columns, then stressed, pushes up on the concrete along its curve. Chosen well, that upward load balances most of the self-weight, so a thinner slab spans further with little deflection and few cracks.
unbonded monostrand: a 7-wire strand,greased, in a plastic sheath,anchored with wedges at the endsthe page: unbonded only;bonded (grouted) tendons are not modelled
Unbonded monostrands. Most SA flat slabs use single greased strands in plastic sheaths. They are not bonded to the concrete: the strand force acts only at the anchors and along the curve. The PT slab calculator models unbonded monostrands; grouted, bonded tendons are not on the page.
aanchor at mid-depthhigh pointover the columnlow pointreverse curve over the column: 0.1 of the span (practice)drape a = mean of the end heights − low point
The tendon profile. Each span is made of parabolas: high over the interior columns, low at mid-span, with a short reverse curve over the column so the tendon has no kink. The drape a sets how much it can lift. The calculator lays out the profile from the covers and takes the reverse curve as 0.1 of the span, a practice value it flags.
wbal = 8 P a / L² per tendontendons per metre× ntargetabout 0.8 of the self-weighttoo little: deflection and cracking; too much: upward camber
Load balancing. A parabolic tendon with force P and drape a over a span L pushes up with 8Pa/L². The number of strands per metre is chosen so that this balances most of the self-weight; the calculator starts at 0.8 of the self-weight (a practice target it flags) and the stress and deflection checks decide.

4. Losses and stresses

losses as the page models them (SANS 10100-1)frictionμ 0.05, K 0.0025/m (5.8.3)wedge draw-in6 mm (practice; the code gives none)elastic shortening½ αe fc (5.8.2.3.3)creepspecific creep (5.8.2.5)shrinkageTable 35 by humidity (5.8.2.4)relaxationlow-relaxation strand (5.8.2.2)
Losses. The jacking force P0 (0.75 fpk Ap, 5.8.1.1) drops at once by friction, wedge draw-in and elastic shortening to Pi, then over time by creep, shrinkage and relaxation to Pe. The calculator works each one from SANS 10100-1 section 5 and uses the average force along the unbonded tendon.
at transferPi, self-weight onlyin servicePe, G + Q patterns≤ 0.45 fci compression≤ 0.33 fcu (0.4 at supports)tension: class 1 none, class 2 limited (Table 30, 5.3.2)
Stresses. The slab is checked uncracked, as P/A ± M/Z with the prestress moment included, twice: at transfer when the prestress is highest and only the self-weight acts, and in service with all the loads. Class 1 allows no tension; class 2 allows a little, with bonded bars near the tension face.

5. Strength, punching and deflection

fpb = fpe + 7 000 / (l / d) (1 − 1.7 fpu Aps / fcu b d)unbonded tendons, SANS 10100-1 eq.(15), ≤ 0.7 fpuULS 1.2G + 1.6Q+ 1.0 the secondary momentbonded barsadd to the strength
Ultimate bending. An unbonded strand does not reach its full strength at failure: SANS 10100-1 eq.(15) gives the stress fpb from the effective prestress and the tendon length. The design moment includes the secondary (hyperstatic) prestress moment at a factor of 1.0 (5.1.4.2, and ACI 318-19 5.3.11 on the page). Bonded bars add to the resistance.
bonded bars over the columns: ACI 318-19 8.6.2.30.000 75 h l within 1.5h of the column faces, at least 4 barsplus SANS 10100-1 5.9.2.2: at least 0.15 % in all
Bonded steel. Unbonded slabs need ordinary bars too: over the columns to control cracking and ductility (ACI 318-19 8.6.2.3, on the page), in the spans where the tension is high, and enough in total for SANS 10100-1 5.9.2.2. The calculator designs them with the strength they add.
interior columns:ACI 318-19 22.6.5.5+ 0.3 fpc from the prestressedge columns: SANSRC route, prestress ignoredb0 at d/2
Punching with prestress. SANS 10100-1 leaves flat slabs to specialist literature, so the page checks interior columns by ACI 318-19 22.6.5.5, where the precompression fpc raises the shear strength, on a perimeter at d/2. Edge columns, which ACI excludes from that rule, go to the SANS reinforced-concrete punching check with the prestress ignored (on the safe side). fpc is the mean P/A of the two directions: the page knows this strip’s own, and you give the other in the input “P/A in the other direction”. Left blank, it takes the 0.862 MPa minimum and warns you.
down under the loads, up from the prestressfinal ≤ L/250; after partitions L/500 or 10 mm; upward L/300
Deflection. With the prestress balancing most of the weight, the slab may hardly move, or even lift. The calculator works the strip deflection with creep from the specific creep of 5.8.2.5, and checks the final, the after-partitions and the upward limits of SANS 10100-1 3.2.3.2.
which code for which checkSANS 10100-1: losses, jacking, stresses, ULS eq.(15),0.15 % steel, fire cover, anchorage bursting, deflectionACI 318-19: minimum P/A, tendon spacing,bonded bars at columns, interior punching
Two codes on one route. SANS 10100-1 section 5 covers prestressed concrete, but says flat slabs follow specialist literature. The page's SANS route therefore uses SANS 10100-1 where it speaks and ACI 318-19 for the flat-slab rules, and every row names its clause. Practice values with no code source (draw-in, the reverse curve, the balance target) are flagged.

6. Example A: a two-span post-tensioned strip

The worked parts open with a university or college email, a student licence (statix.engineering/university/), a calculator pack or a paid plan. Sign in to open them.

7. Example B: a heavier imposed load

The worked parts open with a university or college email, a student licence (statix.engineering/university/), a calculator pack or a paid plan. Sign in to open them.

8. Do it in STATIX

The worked parts open with a university or college email, a student licence (statix.engineering/university/), a calculator pack or a paid plan. Sign in to open them.

9. Common mistakes

The worked parts open with a university or college email, a student licence (statix.engineering/university/), a calculator pack or a paid plan. Sign in to open them.

10. Exercises

The worked parts open with a university or college email, a student licence (statix.engineering/university/), a calculator pack or a paid plan. Sign in to open them.

11. Self-check quiz

The worked parts open with a university or college email, a student licence (statix.engineering/university/), a calculator pack or a paid plan. Sign in to open them.

12. Lesson 2 on one page

The worked parts open with a university or college email, a student licence (statix.engineering/university/), a calculator pack or a paid plan. Sign in to open them.

Next: Lesson 3, RC walls and slender wallsShort and slender walls, in-plane bending and shear with axial load, with the RC wall calculator.
Go to lesson 3

A worked example for learning, not a design. Check every value against the current code and your own project, and have the design checked and signed by a registered professional engineer.

Early access

Be first to use STATIX 3D and STATIX 2D.

Leave your email and we will tell you when each part is ready for testing. One confirmation now, one message then. A short monthly update only if you tick the box.