Slope stability to EN 1997-1
A 10 m high slope at 1 : 2 in one soil layer. Here the factor of safety of the critical slip circle is worked by hand with Bishop's simplified method of slices, then checked for overall stability to EN 1997-1 Design Approach 1. The hand calculation is checked against the STATIX slope stability calculator.
1. The problem
| Input | Value |
|---|---|
| Slope | height H = 10 m at 1 : 2 (vertical : horizontal), 26.6° |
| Ground | 15 m flat in front of the toe, 20 m flat crest behind the slope |
| Firm base | 10 m below the toe (no slip below it) |
| Soil | one layer: c′ = 5 kPa, φ′ = 28°, γ = 19 kN/m³ |
| Water, surcharge | none (dry), no surcharge |
| Method | Bishop simplified, circular slips |
| Target F | 1.5 (practice value) |
2. The method Bishop simplified (Bishop 1955)
A circular block of soil is cut into vertical slices. The factor of safety F is the shear strength along the slip circle divided by the shear stress needed for equilibrium, taken as moments about the circle centre. Bishop's simplified method also takes vertical equilibrium of each slice, with the forces between slices horizontal. F then appears on both sides, so it is found by iteration. This is the method the calculator uses by default; EN 1997-1 section 11 asks for the overall stability check; Bishop's method is one of the usual ways to make it.
3. The critical circle slip search
This step is NOT worked by hand: the critical circle is taken from the calculator, which tries 18 396 circles (a grid of centres and radii, two finer grids around the best one, then a pattern search) and keeps the one with the lowest F. No one does that search on paper. Every step after this one is worked by hand for that one circle. A quick check: the circle passes through the toe, and it meets the crest level y = 10 m at:
4. Slice weights
The block between the toe (x = 15 m) and the crest exit (x = 36.332 m) is cut into 12 slices: 10 slices 2 m wide on the slope face and 2 on the crest. Each slice weight is γ b h, with h the height from the slip circle to the ground at the slice centre. α is the slope of the slip circle under the slice; sin α = (x − x_c) / R. One slice in full, then all of them:
5. The Bishop iteration Bishop simplified
With c′ = 5 kPa and tan φ′ = tan 28° = 0.5317, each slice gives c′ b + W tan φ′, divided by m_α. Start with a guess F = 1.5, work out m_α for every slice, add the terms and divide by Σ W sin α. That gives a new F; repeat until F stops changing. Here: F = 1.5000 → 1.5163 → 1.5186 → 1.5189 → 1.5190. The table is the last round:
6. How many slices
Twelve slices are enough by hand. The same sums with 426 slices (as the calculator uses for the critical circle) give F = 1.5189. The difference is in the fourth decimal: the slice count does not change the answer here.
7. Against the target practice value
There is no code value for a characteristic factor of safety. F ≥ 1.5 for a permanent slope is a common practice value (the calculator's default target, which you can change); it is not a code number.
8. Overall stability to EN 1997-1 EN 1997-1 2.4.7.3.4, 11; Annex A Table A.4
The code check uses Design Approach 1, Combination 2: the soil strengths are divided by the M2 factors γc′ = γφ′ = 1.25 (a variable surcharge would be multiplied by 1.3, but there is none here), and the design Fd must be at least 1.0. The calculator searches again with the design strengths and finds the same circle. With both c′ and tan φ′ divided by the same 1.25, every term divides by 1.25 and m_α stays the same, so Fd = F / 1.25 exactly:
9. The calculator's answer
The calculator, with the same inputs, gives F = 1.518 and Fd = 1.215 (engine 1.1.1, Bishop simplified; it shows a factor of safety rounded down, so it never reads above the true value). The hand calculation with 12 slices gives 1.519 and 1.215. Add a water table 4 m below the crest in the calculator and see how much F drops.
Open the slope stability calculator
A worked example for learning, not a design. Check every value against the current code and your own project, and have the design checked and signed by a registered professional engineer.
Be first to use STATIX 3D.
STATIX 3D is still being built. Join the early-access list and we will tell you when it is ready for testing. One confirmation now, one message then.