RC section stresses and crack width to EN 1992-1-1
A cracked RC section must keep its stresses and its crack width within the limits of EN 1992-1-1 section 7. Here the cracked elastic section and the crack width formula of 7.3.4 are worked by hand for a 300 × 500 mm beam section with three Y20 bars. The hand calculation is checked against the STATIX RC section SLS calculator.
1. The problem
| Input | Value |
|---|---|
| Section | rectangle b × h = 300 × 500 mm |
| Bottom bars | 3 Y20, centres 50 mm above the soffit |
| Top bars | 2 Y12, centres 450 mm above the soffit |
| Concrete / steel | f_ck = 30 MPa, f_yk = 500 MPa, E_s = 200 GPa |
| Moments (N = 0) | characteristic M = 120 kNm, quasi-permanent M = 90 kNm (sagging) |
| Exposure | XC |
| Creep, cover, spacing | φ = 2, c = 35 mm, bar spacing 100 mm |
| Crack width limit | w_max = 0.3 mm |
2. The method EN 1992-1-1 7.2, 7.3.4
At the serviceability limit state the concrete and the steel are taken as linear elastic. Once the concrete tension passes fctm, the section is cracked and the concrete below the neutral axis carries nothing. Two load cases are checked: the characteristic moment (stress limits of 7.2(2) and 7.2(5)) and the quasi-permanent moment (the creep limit of 7.2(3) and the crack width of 7.3.4). For the long-term quasi-permanent case the concrete modulus is reduced for creep.
3. Materials EN 1992-1-1 Table 3.1, 7.4.3(5)
Ecm and fctm come from Table 3.1. The effective modulus for long-term load is Ecm / (1 + φ). The modular ratio αe = Es / Ec turns steel area into equivalent concrete area. φ = 2.0 is the calculator's default creep coefficient: a practice value: work out φ for your own member (age at loading, humidity, size).
4. Is the section cracked?
First the whole section is assumed to work (uncracked), with the bars counted as (αe − 1) As of extra concrete. If the bottom tension is above fctm, the section cracks. As1 = 3 × π × 20² / 4 = 942.5 mm² (bottom), As2 = 2 × π × 12² / 4 = 226.2 mm² (top).
5. Cracked neutral axis, characteristic
With N = 0 the neutral axis is where the first moment of the transformed cracked section is zero: the compression concrete (b x) and the top bars (αe As2) above it balance the bottom bars (αe As1) below it. The depths from the top are d = 450 mm and d2 = 50 mm. That gives a quadratic in x:
6. Stresses, characteristic EN 1992-1-1 7.2(2), 7.2(5)
The cracked second moment of area Icr about the neutral axis gives the stresses by M y / I, times αe for the steel. The 0.6 fck limit of 7.2(2) is required only in XD, XF and XS exposure; this example is XC, so it is shown for information. The steel limit 0.8 fyk of 7.2(5) applies always.
7. Neutral axis and stresses, quasi-permanent EN 1992-1-1 7.2(3)
The same two steps with the long-term αe = 18.272. The softer concrete pushes the neutral axis down. Below 0.45 fck creep can be taken as linear (7.2(3)).
8. Effective tension area EN 1992-1-1 7.3.2(3), Fig. 7.1
The crack width depends on the concrete around the tension bars. Its depth hc,eff is the least of 2.5 (h − d), (h − x) / 3 and h / 2, with x from the quasi-permanent case. Only the 3Y20 bottom bars lie in it.
9. Strain difference EN 1992-1-1 7.3.4(2), eq. 7.9
εsm − εcm is the steel strain less the help the concrete gives between cracks (tension stiffening). kt = 0.4 for long-term load, fct,eff = fctm, and here αe = Es / Ecm = 6.091. It may not be less than 0.6 σs / Es.
10. Crack spacing and crack width EN 1992-1-1 7.3.4, eq. 7.11, 7.8
The bar spacing (100 mm) is below 5 (c + φ/2) = 225 mm (φ = 20 mm, the bar size), so eq. 7.11 applies (not 7.14). k1 = 0.8 (high bond bars), k2 = 0.5 (bending), k3 = 3.4 and k4 = 0.425 (recommended values). c = 35 mm is the cover input of the calculator; with the Y20 centres 50 mm up the clear cover is 40 mm, so 35 mm gives a slightly smaller sr,max. wmax = 0.3 mm is a practice value chosen by the user (the calculator's default, from Table 7.1N).
11. The calculator's answer
The calculator, with the same inputs, gives (engine 1.1.0): characteristic x = 111.3 mm, σc = 16.67 MPa, σs = 308.8 MPa; quasi-permanent x = 169.9 mm, σc = 8.04 MPa, σs = 242.3 MPa; wk = 0.232 mm, and PASS. The hand calculation gives x = 111.3 / 169.9 mm, σc = 16.67 / 8.04 MPa, σs = 308.8 / 242.3 MPa and wk = 0.232 mm. The engine finds the cracked strain plane numerically on 1 mm strips, so the last digit can differ. Raise the quasi-permanent moment to 120 kNm in the calculator and watch the crack width grow.
Open the RC section SLS calculator
A worked example for learning, not a design. Check every value against the current code and your own project, and have the design checked and signed by a registered professional engineer.
Be first to use STATIX 3D.
STATIX 3D is still being built. Join the early-access list and we will tell you when it is ready for testing. One confirmation now, one message then.