RC beam fire resistance to EN 1992-1-2
An RC beam must still carry its load after 90 minutes of a standard fire. Here the simplified 500 °C isotherm method of EN 1992-1-2 Annex B.1 is worked by hand for a 300 × 500 mm beam with three Y20 bars. The hand calculation is checked against the STATIX RC beam and slab in fire calculator.
1. The problem
| Input | Value |
|---|---|
| Member | beam, simply supported, fire on the soffit and both sides |
| Section b × h | 300 × 500 mm |
| Fire | ISO 834, R90; siliceous aggregate |
| Concrete | f_ck = 30 MPa |
| Bottom bars | 3 Y20, axis distance 50 mm (side distance 50 mm) |
| Steel | f_yk = 500 MPa, strength in fire: curve 3 |
| Moment in fire | M_Ed,fi = 100 kNm (sagging) |
2. The method EN 1992-1-2 Annex B.1
The 500 °C isotherm method says: concrete hotter than 500 °C is left out, concrete cooler than 500 °C keeps its full cold strength. The reinforcement keeps its place but loses strength with its temperature. Then the section is checked like a normal beam, with the partial factors for fire, γc,fi = γs,fi = 1.0 (EN 1992-1-2 2.3). Annex B is informative: use it where the National Annex permits.
3. Temperatures in the section EN 1992-1-2 3.3, Annex A basis
This step is NOT worked by hand: the temperatures (the 500 °C depths and the bar temperatures) are taken from the calculator's heat solve, a two-dimensional calculation of the section under the standard ISO 834 fire for 90 minutes, heated on the soffit and both sides. That solve is checked against the temperature profiles of EN 1992-1-2 Annex A for R30 to R120. Every step after this one is worked by hand. Here the 500 °C line is 30.8 mm in from the soffit and 29.6 mm in from each side, and the bars reach:
4. Strength of each bar EN 1992-1-2 4.2.4.3, Fig. 4.2a curve 3
The strength factor ks(θ) of curve 3 drops from 1.0 at 100 °C to 0.7 at 400 °C, 0.57 at 500 °C and 0.1 at 700 °C, linear in between. Curve 3 is the safe choice for any reinforcing steel (not prestressing tendons): it is the 0.2 % proof strength, never above Table 3.2a column 2 (hot rolled) or column 3 (cold worked), and Table 3.2a may be used only when the steel strain reaches 2 % (4.2.4.3).
5. Tension force in the bars
Each Y20 bar has As = π × 20² / 4 = 314 mm². With fyk = 500 MPa and γs,fi = 1.0:
6. The reduced section and the compression block EN 1992-1-2 B.1.3
The width that is cooler than 500 °C is the beam width less the 500 °C depth on each side. The top is not heated, so the compression zone at the top keeps its full depth. The rectangular block of 0.8 x at fck (γc,fi = 1.0) balances T:
7. Bending resistance in fire
The moment resistance is the bar force times the lever arm. The design moment in fire comes from the accidental combination of EN 1990 6.4.3.3: Gk + (ψ1,1 or ψ2,1) Qk,1 + ψ2,i Qk,i (the National Annex sets the ψ1 / ψ2 choice). As a simplification, EN 1992-1-2 2.4.2 allows Ed,fi = ηfi Ed with ηfi = 0.7.
8. The calculator's answer
The calculator, with the same inputs, gives MRd,fi = 124.2 kNm (engine 1.4.2) and PASS. The hand calculation above uses its bar temperatures and gives the same number. If the bars were 10 mm lower (axis distance 40 mm), they would be hotter and the resistance would drop: try it in the calculator.
Open the RC beam and slab in fire calculator
A worked example for learning, not a design. Check every value against the current code and your own project, and have the design checked and signed by a registered professional engineer.
Be first to use STATIX 3D.
STATIX 3D is still being built. Join the early-access list and we will tell you when it is ready for testing. One confirmation now, one message then.