RC Beam, Slab and Column Fire Resistance Calculator
An RC beam (heated from below and both sides) or a slab strip (heated from below), or a braced column (heated on all four faces, EN 1992-1-2 Annex C tables), in the ISO 834 fire: the temperatures in the section, each bar's temperature and strength, the 500 °C isotherm method of EN 1992-1-2 Annex B.1 and the bending resistance in fire, with every check and a step-by-step calc sheet. Validated range R30 - R120.
EN 1992-1-2 B.1 · Annex A · Annex C
Section
mm
mm
Fire ISO 834
min
Materials & action
MPa
MPa
kNm
kN
kNm
kNm
mm
MEd,fi / MRd,fi—
Bottom bars height above the soffit
| Layer | y mm | Bars n | Size |
|---|---|---|---|
| 1 | |||
| 2 | |||
| 3 | |||
| 4 |
mm
Each layer: its centre height y above the soffit (the axis distance), the number of bars and their size. A beam spreads the bars from asd to b − asd; a slab strip spaces them evenly. A row with y or n blank is not used.
mm
Column: the bars sit all round, the same size, at the axis distance a from every face; each face has the stated number (the corner bars count on both faces).
Validated range (columns): Braced columns: EN 1992-1-2 Annex C tables, R30 - R240, lambda_fi ≤ 80, n ≤ 0,7, 0,1 ≤ omega ≤ 1,0, e ≤ 0,5b and ≤ 200 mm. No interpolation: the column must meet every bracketing table cell. Outside -> NOT CHECKED. The 500 °C isotherm + nominal curvature route is shown as information. A column that is not braced, or whose bracing is not given, is NOT CHECKED. The column route has no public verification card yet (the card covers beams and slabs).
Validated range: R30 - R120, ISO 834 fire; a slab h ≥ 200 mm; a beam b ≥ 300 mm and h ≥ 300 mm. The temperatures are checked against EN 1992-1-2 Annex A in this range; outside it the result is NOT CHECKED with the reason. Calcareous aggregate uses the siliceous temperatures (the safe side). The bar strength ks(θ) is EN 1992-1-2 Fig. 4.2a curve 3 by default (the safe side); hot rolled / cold worked (Table 3.2a) apply only when the steel strain is 2 % or more.
Section
Section, heated faces, the zone above 500 °C, bar temperatures
Design checks
| Check | Clause | Demand / capacity | Utilisation | Result | |
|---|---|---|---|---|---|
| Checking on the STATIX server… | |||||
Check details as text
—
—
enter the section, the bars and the fire rating
Result
| 500 °C depth a500 bottom / sides | — |
| Hottest bar θ with ks(θ) | — |
| Reduced section bfi / x / z | — |
| MRd,fi 500 °C isotherm, B.1.3 | — |
| Annex C: ω / n / λfi / e | — |
| Bracketing table cells all must be met | — |
| Validated range | — |
Step-by-step calculation
Loading the calc sheet from the STATIX server… Start your free 14-day trial for every check and the calc sheet.
The fire check here, the cold design next door
The bars, the shear and the deflection at normal temperature are on the RC beam calculator. Free 14-day trial.