Pre-tensioned prestressed beam to SANS 10100-1
A pre-tensioned beam is checked three times: at transfer, in service and at the ultimate limit state. Here a 900 mm deep I beam with eight 12.5 mm strands over a 12 m span is worked by hand to SANS 10100-1 Section 5. The hand calculation is checked against the STATIX prestressed beam calculator.
1. The problem
| Input | Value |
|---|---|
| Section | I beam, h = 900 mm; top flange 400 × 150, web 150, bottom flange 400 × 200 mm |
| Span | 12 m, simply supported |
| Loads | G = 10 kN/m and Q = 15 kN/m on top of the self weight (24 kN/m³) |
| Strands | 8 × 12.5 mm low-relaxation, centroid 60 mm above the soffit, jacked to 75 % f_pu |
| Concrete | f_cu = 50 MPa, f_ci = 35 MPa at transfer |
| Exposure | relative humidity 70 %; class 2 (tension, no visible cracks) |
2. The method SANS 10100-1 Section 5
The strands are stressed against the bed, the concrete is cast around them, and at transfer the strands are cut: the concrete takes the prestress. The prestress then falls with elastic shortening, shrinkage, creep and relaxation. The beam is checked at transfer (the full early prestress, self weight only, the young concrete), in service (the prestress after all losses, the full service load) and at the ultimate limit state. Prestressed concrete is Section 5 of SANS 10100-1 (as in BS 8110-1); the loads follow SANS 10160-1. Compression is positive.
3. Section properties by parts
The I section is three rectangles: the bottom flange 400 × 200, the web 150 × 550 and the top flange 400 × 150 mm. The strands sit 60 mm above the soffit.
4. Loads and moments SANS 10160-1
The self weight is the area times 24 kN/m³. The ultimate load is the larger of 1.2 G + 1.6 Q and 1.35 G + 1.0 Q. The span is 12 m, simply supported.
5. Jacking and elastic shortening SANS 10100-1 5.8.1.1, 5.8.2.3.2, Table 1, 3.4.2.3
Eight 12.5 mm strands of 93 mm² and fpu = 1770 MPa each (manufacturer figures, not code values), jacked to 75 % of fpu (the normal limit of 5.8.1.1). At transfer the concrete shortens and the strands with it. The loss is the modular ratio times the concrete stress at the strands, where the self weight helps. Solving P0 = Pi − α Aps fc together with fc gives P0 in one line. Eci is read from Table 1 at fci = 35 MPa, Es = 195 GPa (3.4.2.3).
6. Stresses at transfer SANS 10100-1 5.3.2.3.1, 5.3.2.3.2, Table 30
At midspan the prestress after the elastic loss acts with the self weight. The distribution is triangular (the top stress is far below half the bottom one), so the compression limit is 0.45 fci; class 2 allows tension up to 0.45 √fci at transfer.
7. Long-term losses SANS 10100-1 5.8.2.4.2 Table 35, 5.8.2.5.2, 5.8.2.5.4, 5.8.2.2.2
Shrinkage: Table 35 (pre-tensioned) gives the strain at 80, 60 and 35 % relative humidity. Between two rows the calculator takes the drier row and says so in a note (the safe side for the loss): for the default 70 % that is the 60 % row, 310 × 10⁻⁶ (more shrinkage than an interpolated 70 % value, so a larger loss). Creep: the specific creep is 48 × 10⁻⁶ per MPa × 40 / fci for fci ≤ 40 MPa; it is not increased because the largest transfer stress, 9.647 MPa, is below fci / 3 = 11.667 MPa. Relaxation: 10 % at 80 % of fpu falling linearly to 3 % at 50 %, with 8.5 % in place of 10 % once creep plus shrinkage passes 500 × 10⁻⁶; halved for low-relaxation strand.
8. Stresses in service SANS 10100-1 Table 29, Table 30
The prestress after all losses acts with the full service moment. Compression in bending is limited to 0.33 fcu (Table 29); class 2, pre-tensioned, allows flexural tension up to 0.45 √fcu (Table 30).
9. Ultimate moment SANS 10100-1 5.3.3.2.1, 5.3.3.2.2, 5.3.3.2.3 Table 32, 5.3.3.2.5(a)
Table 32 gives the strand stress fpb at failure and the neutral axis depth x for bonded tendons from fpu Aps / (fcu b d) and fpe / fpu. Here fpe / fpu = 0.6004 is just above 0.6, the highest column, so the 0.6 column is used (5.3.3.2.5(a)). Between the rows 0.05 and 0.10, fpb / 0.87 fpu is 1.00 in both, and x / d goes from 0.11 to 0.22, interpolated linearly. Then Mu = fpb Aps (d − 0.45 x) (5.3.3.2.1, 5.3.3.2.2). The calculator also finds the block depth from equilibrium and takes the lesser moment.
10. The calculator's answer
The calculator, with the same inputs, gives fpe = 1062.7 MPa after 20.0 % losses, transfer stresses 9.65 (bottom) and −1.55 MPa (top), service stresses 9.18 (top) and −1.70 MPa (bottom), and Mu = 887.7 kNm against 763.3 kNm (engine 1.0.1), PASS. The hand calculation gives the same numbers. The calculator also designs the shear links (5.3.4) and checks the deflection and camber; those are not worked here. Try 6 strands, or a jacking force of 70 %, and watch the service tension and Mu.
Open the prestressed beam calculator
A worked example for learning, not a design. Check every value against the current code and your own project, and have the design checked and signed by a registered professional engineer.
Be first to use STATIX 3D.
STATIX 3D is still being built. Join the early-access list and we will tell you when it is ready for testing. One confirmation now, one message then.