STATIX SANS · Eurocode · BS 8110 Find a calculator…48 Start free trial
Learn · worked example

Precast beam with an in-situ topping to EN 1992-1-1

A precast beam first carries the wet topping on its own, then works together with the hardened topping. Here a 300 × 400 mm precast beam with a 1000 × 100 mm topping is worked by hand: the bending resistance of each stage and the shear across the joint, to EN 1992-1-1. The hand calculation is checked against the STATIX composite precast beam calculator.

1. The problem

InputValue
Precast beam b × h300 × 400 mm, f_ck = 40 MPa
Topping b_t × h_t1000 × 100 mm (the width acting with the beam), f_ck = 30 MPa
Bottom bars5 Y25 at 50 mm above the soffit, f_yk = 500 MPa
Moments (ULS)stage 1, precast alone: M_1,Ed = 80 kNm; total on the composite: M_Ed = 250 kNm
Shear at the jointV_Ed = 150 kN
Jointrough surface, links crossing A_si = 1000 mm²/m at 90°, joint width b_i = b, σ_n = 0
Concrete factorα_cc = 0.85
Shear linksY8, 2 legs at 200 mm (the calculator's default; for the member shear)

2. The method EN 1992-1-1 6.1, 3.1.7(3)

A precast beam carries the wet topping and the construction load on its own (stage 1). Once the topping hardens, the two act together (stage 2). At the ultimate limit state the order of loading does not change the plastic resistance, so stage 1 checks the stage 1 moment on the precast alone and stage 2 checks the TOTAL moment on the composite section. Each resistance uses the rectangular block of 0.8 x at fcd with εcu3 = 0.0035 at the top (3.1.7(3)), and the bars at fyd once they yield. The joint between the precast and the topping must carry the shear flow (6.2.5).

block 0.8x = 62.8 mm (stage 2)interface 6.2.5topping 1000 × 100, C30precast 300 × 400, C405 Y25 at 50 mm

3. Materials and the bars EN 1992-1-1 3.1.6, 3.2.7

αcc = 0.85 is the calculator's default (the EN recommended value; the SANS 51992 annex uses 1.0). γc = 1.5, γs = 1.15.

f_cd,precast = 0.85 × 40 / 1.5 = 22.667 MPa f_cd,topping = 0.85 × 30 / 1.5 = 17.000 MPa f_yd = 500 / 1.15 = 434.78 MPa, ε_yd = f_yd / E_s = 434.78 / 200000 = 0.00217 A_s = 5 × π × 25² / 4 = 5 × 490.87 = 2454.4 mm² T = A_s f_yd = 2454.4 × 434.78 / 1000 = 1067.12 kN

4. Stage 1: the precast alone EN 1992-1-1 6.1, 3.1.7(3)

The block of depth 0.8 x and width b balances the bar force. Then check that the bars really yield: the strain at the bars must be at least εyd.

d = 400 − 50 = 350 mm x = T / (0.8 b f_cd) = 1067.12 × 1000 / (0.8 × 300 × 22.667) = 196.16 mm ε_s = 0.0035 × (d − x) / x = 0.0035 × (350 − 196.16) / 196.16 = 0.00274 ≥ 0.00217 the bars yield z = d − 0.4 x = 350 − 0.4 × 196.16 = 271.54 mm M_Rd,1 = T z = 1067.12 × 271.54 / 1000 = 289.76 kNm ≥ M_1,Ed = 80 kNm OK, 28 %

5. Stage 2: the composite section EN 1992-1-1 6.1, 3.1.7(3)

Now the compression is in the 1000 mm wide topping, at the topping's fcd. If the block 0.8 x is no deeper than the topping, all of it is in the topping concrete and the share of the compression in the topping is β = 1.0. The bars are 100 mm deeper than in stage 1.

d = 400 + 100 − 50 = 450 mm x = 1067.12 × 1000 / (0.8 × 1000 × 17.000) = 78.46 mm, 0.8 x = 62.77 mm ≤ h_t = 100 mm → β = 1.0 ε_s = 0.0035 × (450 − 78.46) / 78.46 = 0.01657 ≥ 0.00217 the bars yield z = 450 − 0.4 × 78.46 = 418.61 mm M_Rd,2 = 1067.12 × 418.61 / 1000 = 446.71 kNm ≥ M_Ed = 250 kNm OK, 56 %

6. Interface shear: the stress EN 1992-1-1 6.2.5, eq. 6.24

The shear flow across the joint is the change in the topping compression along the beam. Per unit area of the joint it is vEdi = β VEd / (z bi), with z the composite lever arm from stage 2 and bi the joint width, here the precast width (the calculator's default when bi is blank).

v_Edi = β V_Ed / (z b_i) = 1.0 × 150 × 1000 / (418.61 × 300) = 1.1944 MPa

7. Interface shear: the resistance EN 1992-1-1 6.2.5, eq. 6.25, 6.2.5(2), 6.6N

The joint resists by adhesion (c), friction (μ) and the links that cross it. For a rough surface c = 0.40 and μ = 0.7 (6.2.5(2)). There is no normal stress across the joint (σn = 0). The links are 1000 mm² per metre of joint, at α = 90°. The calculator takes fctd and fcd of the weaker concrete, the C30 topping: the safe side, since the code does not say which. αct = 1.0.

f_ctm = 0.3 × 30^(2/3) = 2.8965 MPa, f_ctk,0.05 = 0.7 × 2.8965 = 2.0275 MPa, f_ctd = 2.0275 / 1.5 = 1.3517 MPa ρ = A_si / A_i = 1000 / (300 × 1000) = 0.003333 v_Rdi = c f_ctd + μ σ_n + ρ f_yd (μ sin α + cos α) = 0.40 × 1.3517 + 0 + 0.003333 × 434.78 × (0.7 × 1 + 0) = 0.5407 + 1.0145 = 1.5552 MPa limit 0.5 ν f_cd: ν = 0.6 × (1 − 30 / 250) = 0.528, 0.5 × 0.528 × 17.000 = 4.488 MPa (not reached) v_Edi = 1.1944 MPa ≤ v_Rdi = 1.5552 MPa OK, 77 %

8. The calculator's answer

The calculator, with the same inputs, gives MRd = 289.8 kNm for stage 1 and 446.7 kNm for the composite section, vEdi = 1.194 MPa against vRdi = 1.555 MPa (engine 1.3.0), and PASS. The hand calculation gives the same numbers. The calculator also checks the staged service stresses of EN 1992-1-1 7.2 (from M1,k = 55 kNm and M2,k = 110 kNm, its other defaults): precast top 8.76 MPa, topping top 5.19 MPa, steel 181.6 MPa, all within their limits, and the member shear of the precast web at the composite depth (EN 1992-1-1 6.2.3) with Y8 links, 2 legs at 200 mm: 69 % used. They are not worked here. Change the surface to smooth, or remove the links, and watch the interface check.

z 419ULS neutral axis x = 78 mm; block 63 mm (100 % in the topping)interface (the joint) - governsstage 2 neutral axis 398 mm (composite)stage 1 neutral axis 260 mm (the precast alone)5 × Ø25 at 50 mmb 300b_t 1000h 400h_t 100M_Rd 446,71 kNm composite, 289,76 kNm the precast alonebars: their heights from the result, spread across the width (their places across are not in the result)governs: the interface
Schematic: the precast and topping section to scale with the interface, the bars at their heights, the ULS stress block and the stage 1 / stage 2 neutral axes from the result. Not a detail. Drawn by the calculator from its own run of this example (PASS).
Run this example yourselfOpen the STATIX composite precast beam calculator. These are the calculator's default inputs, so it opens on this example. Change any value and the result updates, with every check and a calc sheet.
Open the composite precast beam calculator

A worked example for learning, not a design. Check every value against the current code and your own project, and have the design checked and signed by a registered professional engineer.