Anchor reinforcement to EN 1992-4
An anchor carries 60 kN tension and 30 kN shear towards an edge 150 mm away. Instead of relying on the concrete cone and edge, bars round the anchor take the load. Here EN 1992-4 7.2 is worked by hand for those bars. The hand calculation is checked against the STATIX anchor reinforcement calculator.
1. The problem
| Input | Value |
|---|---|
| Concrete | f_ck = 30 MPa, good bond |
| Bars | f_yk,re = 500 MPa |
| Anchor | h_ef = 200 mm; the most loaded anchor of the group |
| Tension | N_Ed = 60 kN on that anchor |
| Shear towards the edge | V_Ed = 30 kN, edge distance c1 = 150 mm, lever e_s = 0 mm, member depth not limiting |
| Tension bars | 4 Y12 at 100 mm from the anchor, l1 = 150 mm in the cone, hooked |
| Edge bars | 2 Y12 surface bars at 75 mm from the anchor, l1 = 150 mm, hooked |
| Confirmations | both boxes ticked: the same bars round every anchor; anchorage outside the cone and surface bars detailed |
2. The method EN 1992-4 7.2.1.2, 7.2.2.2
An anchor near an edge or in thin concrete may fail by pulling out a cone of concrete (tension) or by breaking off the edge (shear). EN 1992-4 lets you put bars round the anchor that catch that cone or edge: then the concrete cone (7.2.1.2(1)) and the concrete edge failure (7.2.2.2(1)) need not be verified, and the bars carry the total load of the anchor. The calculator checks the bars round the most loaded anchor. That is valid only when the same bars sit round every anchor of the group (7.2.1.2(2) b), 7.2.2.2(3) a)); in this example the reader confirms it with the first box. The anchor's own checks (steel, pull-out, splitting, pry-out) and the base plate stay on the base plate calculator.
3. Which bars count EN 1992-4 7.2.1.2(2) a, c, d; 7.2.2.2(3) b - d
A bar counts only if it is no larger than φ16, its fyk is at most 600 MPa, it is close to the anchor (tension: within 0.75 hef; edge: within 0.75 c1) and it reaches far enough into the cone or the broken-off edge: l1 ≥ 4φ with a hook, bend or loop, 10φ when straight. l1 is measured from where the cone face crosses the bar, and in tension it can count only up to the depth of the cone at the bar, hef − dist / 1.5 (the cone spreads at 1.5 hef): a longer bar is cut to that depth.
4. Design bond strength EN 1992-1-1 8.4.2
The bars hold in the cone by bond. fbd = 2.25 η1 η2 fctd, with η1 = 1.0 for good bond, η2 = 1.0 for φ ≤ 32 and fctd = fctk,0.05 / 1.5 with αct = 1.0 (the value the calculator uses; the National Annex may set αct).
5. Tension: steel of the bars EN 1992-4 7.2.1.9.1, eq. 7.31; γ_Ms,re = 1.15
NEd,re is the whole tension on the most loaded anchor (6.4.2), here NEd = 60 kN. The bars must carry it at their design yield strength, γMs,re = 1.15.
6. Tension: anchorage of the bars in the cone EN 1992-4 7.2.1.9.2, eq. 7.32 / 7.33; EN 1992-1-1 8.4.4
Each bar can pull out of the cone only by bond over l1: l1 π φ fbd / (α1 α2), and never more than its own steel strength. α1, α2 are the EN 1992-1-1 8.4.4 factors for the shape and the cover; the calculator takes 1.0 for both, the safe side.
7. Shear: the tension in the edge bars EN 1992-4 6.4.3, eq. 6.6
The shear towards the edge is carried by the bars as a tie of a strut-and-tie model. If the shear acts at a distance es from the bars, the tie force grows by es / z, with z = 0.85 d and d no more than 2 hef or 2 c1. The member depth was left blank, so it does not limit d. Here es = 0, so NEd,re = VEd.
8. Shear: steel of the edge bars EN 1992-4 7.2.2.6.2, eq. 7.51
For surface bars (Fig. 7.10 a) the factor k10 = 1.0; for loops or stirrups in contact with the anchor it would be 0.5.
9. Shear: anchorage of the edge bars EN 1992-4 7.2.2.6.3(2), eq. 7.52 / 7.53
Surface bars must also be anchored in the broken-off edge by bond, worked as for tension. As in tension, l1 counts only up to the depth of the break-out body at the bar, c1 − dist / 1.5 (the edge failure spreads at 1.5 c1). (Loops or stirrups in contact with the anchor need no such proof, 7.2.2.6.3(1).)
10. What the engineer confirms EN 1992-4 7.2.1.2(2) e, f; 7.2.2.2(2), (3) f
Two things the calculator cannot see. The bars must also be anchored outside the cone or the broken-off edge (lbd to EN 1992-1-1, or lapped into the member's own bars), and the surface and edge bars must be designed for the strut-and-tie forces and splitting. The page asks you to confirm this with the second box, and the same bars round every anchor with the first. Until both boxes are ticked the calculator answers NOT CHECKED: it never assumes them.
11. The ratios for the interaction EN 1992-4 7.2.3.2
With effective bars, βN,re and βV,re take the place of the cone and edge ratios in the anchor's combined tension and shear check (Table 7.3 line 2, eq. 7.57), which is made on the base plate calculator.
12. The calculator's answer
The calculator, with the same inputs and both boxes ticked, gives NRd,a = 61.1 kN, NRd,a (edge) = 22.9 kN, βN,re = 0.982, βV,re = 1.309 and FAIL (engine 1.0.5; it rounds a demand up and a capacity down). The hand calculation gives the same. Here the bond governs, not the steel: the tension bars pass, but the edge bars are too short inside the break-out body, so the shear FAILS. Try the edge bars closer to the anchor, more of them, or a larger edge distance c1 in the calculator and see the edge check pass.
Open the anchor reinforcement calculator
A worked example for learning, not a design. Check every value against the current code and your own project, and have the design checked and signed by a registered professional engineer.
Be first to use STATIX 3D.
STATIX 3D is still being built. Join the early-access list and we will tell you when it is ready for testing. One confirmation now, one message then.