STATIX SANS · Eurocode · BS 8110 Find a calculator…48 Start free trial
Learn · worked example

RC beam with a web opening

A duct through a beam web cuts the beam into two chords. Here the Vierendeel chord method is worked by hand: first the force split of a published test beam, then a SANS 10100-1 beam with a 400 x 180 mm opening. The hand calculation is checked against the STATIX RC beam web opening calculator.

1. The method

A web opening cuts the beam into a top chord and a bottom chord. Over the opening the beam works as a Vierendeel frame. The moment M becomes a pair of axial forces in the chords. The shear V is shared by the chords and bends each one. Each chord is then checked as a short member under N, M and V.

This is the Vierendeel chord method (Mansur & Tan; PCI Journal 1977). The design codes give no clause for web openings. The chords are checked to the section rules of the code you choose. This example has two parts:

  • Part A: the force split of a published beam, checked against the paper.
  • Part B: a SANS 10100-1 beam, the calculator's starting values, checked by hand.

2. Part A: the published check PCI Journal, Nov-Dec 1977, App. B

Source: Barney, Corley, Hanson, Parmelee, "Behavior and Design of Prestressed Concrete Beams with Large Web Openings", PCI Journal, Nov-Dec 1977, Appendix B. The paper is free on pci.org.

Limit of this part. The paper's beam is a prestressed double tee with a 50 mm topping (ACI 318-71). The calculator designs reinforced concrete only: no prestress, a rectangular section. So the calculator cannot run this beam. Part A checks the force split only (statics). There is no calculator run, no figure and no code check.

Units: 1 in = 25,4 mm; 1 kip = 4,448 kN; 1 in-kip = 0,1130 kNm.

Hole A (centre 8,5 ft from the support)PaperSIEngine (SI)
M_u1066 in-kip120,4 kNm120,4 kNm
V_u (V_d dead 2,9 kip)7,2 kip32,0 kN32,0 kN
d_s (lever arm of the struts)17,57 in446 mm446 mm
V_c = V I_c / (I_c + I_t,cr) = 7,2 x 214 / (214 + 72)5,4 kip24,0 kN24,0 kN
V_t = V_d I_t / (I_c' + I_t) + (V - V_d) I_t / (I_c + I_t)6,0 kip26,7 kN26,6 kN
M_c = V_c x 19 in (hinge at mid-length, strut 38 in)102,6 in-kip11,6 kNm11,6 kNm
M_t = V_t x 19 in114,0 in-kip12,9 kNm12,9 kNm

Hole B: T = 31,9 kip > 6 A_g √f_c' = 24,7 kip. A crack goes through the full depth of the tension strut. The compression strut carries all of V: V_c = 2,3 kip (10,2 kN), V_t = 0, M_t = 0. The engine gives the same.

A note on N. The paper's C = 60 kip and T = 10,8 kip include the prestress P. The calculator has P = 0, so N = M / d_s = 270 kN at Hole A. The difference comes from the prestress. It is not an engine error.

3. Part B: the problem SANS 10100-1

These are the calculator's starting values, with the corner bar statement ticked.

InputValue
Beamb 300 mm, h 600 mm
Materialsf_cu 30 MPa, f_y = f_yv 450 MPa
Cover and linkscover 30 mm, Y10 links
Opening400 x 180 mm; top chord h_t 220 mm, bottom chord h_b 200 mm; 900 mm clear from the support
Actions at the centre of the openingM 100 kNm (sagging), V 70 kN
Bars3Y16 top + 2Y16 above the opening; 3Y20 bottom + 2Y16 below the opening
Linkschord links Y10 at 100 mm; full-depth links within e_s = 50 mm of each edge
3Y16 top2Y16 top, at the opening2Y16 bottom, at the opening3Y20 bottomh_b 200h_o 180h_t 220z 390l_o 400 (l_eff 500)e_s 50openingb 300SECTION AT THE OPENINGM 100 kNm (sagging), V 70 kN at the openingtop chord: N 256 C kN, V 70 kN, M ±17,5 kNm · 0,82bottom chord: N 256 T kN, V 0 kN, M ±0 kNm (cracked through: all V in the other chord) · 0,59full-depth links each side within e_s 50 mm: A_v 179 mm²corner diagonals (dashed): 126 mm² each corner - practice, the user confirms themgoverns: the top chord
Schematic: the beam elevation and the section through the opening to scale, the bar layers at their heights, the chord forces and utilisations from the result. Not a detail. Drawn by the calculator from its own run of this example (PASS).

4. Lever arm and chord force statics

The chord forces act at the centre of each chord. The top chord is in compression and the bottom chord in tension.

z = 600 - 220/2 - 200/2 = 390 mm N = M / z = 100 / 0,390 = 256,4 kN

5. Which chord carries the shear method (Mansur)

Compare the cracking force of the bottom chord with its tension.

A f_ct = 300 x 200 x 0,3 x 24^(2/3) = 149,5 kN < 256,4 kN

The bottom chord is cracked through. So the top chord carries all of V: V_c = 70 kN, V_t = 0.

6. Chord moment method

The chord bends in double curvature over its effective length, with the hinge at mid-length.

l_eff = l_o + 2 e_s = 400 + 2 x 50 = 500 mm M_c = V_c l_eff / 2 = 70 x 0,5 / 2 = 17,5 kNm

7. Top chord: N + M SANS 10100-1 section rules, strain compatibility

The shift rule adds V times the chord's effective depth, d_c = 220 - 30 - 10 - 8 = 172 mm.

M_E = 17,5 + 70 x 0,172 = 29,54 kNm

The engine checks N-M at the gross N (256,4 kN) and at the z_ub N (192,5 kN), and uses the worse. M_Rd = 35,85 kNm at N 192,5 kN.

util = 29,54 / 35,85 = 0,824 (governs)

8. Top chord: shear SANS 10100-1 4.3.4

v = 70 000 / (300 x 172) = 1,357 MPa ≤ v_max = min(0,75 √30, 4,75) = 4,108 MPa v_c0 = (0,79 / 1,4) x 0,779^(1/3) x (400/172)^(1/4) x (30/25)^(1/3) = 0,681 MPa

The axial force adds to the concrete shear strength.

0,6 x 192 500 / 66 000 x min(1, 70 x 0,22 / 17,5) = 1,540 MPa v_c = 2,221 MPa > v

So minimum links are sufficient.

required: 0,4 x 300 / (0,87 x 450) = 0,307 mm²/mm provided: 2 legs Y10 at 100 = 1,571 mm²/mm util 0,195

9. Top chord: link spacing SANS 10100-1 4.11.5

s_v 100 ≤ 0,75 d_c = 129 mm util 0,775 (a minimum row)

10. Bottom chord SANS 10100-1 section rules

The bottom chord takes N = 256,4 kN in tension. For the shift only, the uncracked stiffness share gives it a shear.

V_t = 70 x 200³ / (220³ + 200³) = 30,0 kN M_E = 30,0 x 0,152 = 4,56 kNm util 0,590

11. Links beside the opening method (PCI 1977 App. B step 6)

A_v = V / (0,87 f_yv) = 70 000 / 391,5 = 179 mm²

Provide this as full-depth links on each side, within 50 mm of the opening edge.

12. Corner bars practice rule, not a code value

A = V / (2 f_yd sin 45°) = 126 mm² per corner

This is a practice rule. You confirm the corner bars in the calculator.

13. The calculator's answer

The calculator, with the same inputs (engine 1.0.5), reads NOT CHECKED until you confirm the corner bars (a practice rule, never pre-ticked); then PASS, governing utilisation 0,824 (top chord N-M). The bottom chord N-M is 0,59. It asks for full-depth links of 179 mm² each side and corner bars of 126 mm² per corner. The hand calculation gives the same numbers.

Run this example yourselfOpen the STATIX RC beam web opening calculator. It opens on the Part B inputs; tick the corner bar statement to get this result. Change any value and the result updates, with every check and a calc sheet.
Open the RC beam web opening calculator

A worked example for learning, not a design. Check every value against the current code and your own project, and have the design checked and signed by a registered professional engineer.

Early access

Be first to use STATIX 3D.

STATIX 3D is still being built. Join the early-access list and we will tell you when it is ready for testing. One confirmation now, one message then.

Get early access