Eaves haunch connection to EN 1993-1-8
A portal rafter is bolted to its column through an extended end plate, deepened by a 300 mm haunch. Here the component method of EN 1993-1-8 is worked by hand for the bolt rows, the compression side and the column web, up to the moment resistance and the welds. The hand calculation is checked against the STATIX eaves haunch connection calculator.
1. The problem
| Input | Value |
|---|---|
| Rafter | 457 × 191 × 67 UB, S355 |
| Column | 305 × 305 × 137 UC, S355; it ends 15 mm above the end plate (no cap) |
| Haunch | cut from the rafter (t_fh = t_f = 12.7 mm), 300 mm deep below the rafter, 500 mm long |
| End plate | extended, 180 mm wide, 20 mm thick, S355 (f_y = 345 MPa at 20 mm); depth set by the engine |
| Bolts | M20 class 10.9, gauge 100 mm, 4 tension rows inside the rafter + 1 above it at 80 mm pitch, 1 shear row below the haunch |
| Welds | fillets, 8 mm legs to the flanges and the web; haunch welds 6 mm |
| Roof pitch | 10° (the page's required Roof pitch input, page default 10°) |
| Design actions | M = 220 kNm (gravity: tension at the rafter top), V = 120 kN, N = 0 |
2. The method EN 1993-1-8 6.2 (component method), 6.2.6.7(2) (haunch)
An eaves haunch deepens the rafter where it meets the column, so the bolts in tension sit far from the centre of compression and the joint resists a larger moment. The calculator runs the STATIX app's end plate engine on the haunch-deepened section: each bolt row gets a tension resistance from the weakest of its T-stubs (end plate, column flange) and its bolts, then the rows, the row groups, the compression zone and the column web panel are checked together. The page's "Cut from" is Rafter cutting by default, so the haunch is a cutting of the same 457 × 191 × 67 UB and its flange is the rafter flange, tfh = tf = 12.7 mm (the page fixes it today). γM0 = 1.0, γM2 = 1.25.
3. The joint geometry engine layout
The engine lays out the plate itself: one row 40 mm above the rafter top fibre, the other tension rows down from there at the 80 mm pitch, and a shear row 40 mm below the haunch flange. The end distance is 1.5 d0 = 33 mm rounded up to 35 mm (a practice value of the engine, above the 1.2 d0 minimum of Table 3.3). The roof pitch is the page's input (Roof pitch, required; 10° here, the page default): the rafter is cut plumb at 10°. One number here is taken from the calculator, not worked by hand: the slanted haunch flange is 16.15 mm deep where the plate cuts it (the engine's drawn geometry). The centre of compression is the middle of that flange. Every later step is worked by hand, except the chart reading α of Figure 6.11 for row 2 and the other checks near the end, which are said to come from the calculator.
4. Bolt resistances EN 1993-1-8 3.6.1, Table 3.4
M20 class 10.9: tensile stress area As = 245 mm², fub = 1000 MPa. For class 10.9 the shear factor αv is 0.5 (the shear plane through the thread).
5. Row 1, above the rafter: end plate and column flange EN 1993-1-8 6.2.6.5, 6.2.6.4, 6.2.4 Table 6.2, Tables 6.4 and 6.6
The extension of the end plate is a T-stub bent about the rafter flange: mx is the bolt to the weld toe (0.8 × the 8 mm leg), ex the bolt to the plate top. The column ends 15 mm above the plate, so on the column side row 1 is an END row of Table 6.4. Each T-stub gives mode 1 (plate yields), mode 2 (plate yields with prying, bolts break) and mode 3 (bolts break); the lowest governs. fy = 345 MPa for the 20 mm plate and the 21.7 mm column flange (S355, 16 to 40 mm).
6. Rows 3 to 5, and the column flange of rows 2 to 5 EN 1993-1-8 6.2.6.5, 6.2.6.4, 6.2.6.3, 6.2.6.8, Tables 6.4 and 6.6
Inside the rafter the end plate T-stub spans from the bolt to the web weld toe. Rows 3, 4 and 5 are inner rows of Table 6.6 (row 2, next to the flange, follows in the next step). On the column every row below row 1 is an inner row of Table 6.4. The column web in tension (6.2.6.3, with ω and beff = ℓeff,1 of the column flange) and the rafter web in tension (6.2.6.8) are stronger.
7. Row 2: the end plate next to the rafter flange EN 1993-1-8 6.2.6.5, Table 6.6, Figure 6.11
Row 2 is the first bolt row below the rafter tension flange, and the flange stiffens its T-stub. Table 6.6 gives this row ℓeff,cp = 2πm and ℓeff,nc = αm. α depends on λ1 = m / (m + e) and λ2 = m2 / (m + e), where m2 is the bolt to the toe of the flange weld: the flange inner face (the rafter top fibre less the flange depth on the plumb cut, 12.7 / cos 10°) less the row, less 0.8 × the 8 mm leg. α is read from Fig. 6.11 by the calculator: α = 6.3474 at λ1 = 0.4959, λ2 = 0.3005 (a chart reading, not worked here; the calculator takes the lowest α along λ1 up to this value, so α never rises as λ1 grows). Everything after α is worked by hand.
8. Row groups EN 1993-1-8 6.2.4.2, 6.2.6.4, 6.2.6.5, Tables 6.4 and 6.6
Rows close together share their yield lines, so every run of adjacent rows is also checked as a group: on the column flange rows 1 to 5, on the end plate rows 2 to 5 (the extension row 1 is a T-stub of its own). Σℓeff adds a length per row: an end row of the group 2m + 0.625e + 0.5p (non-circular) and πm + p (circular), an inner row p and 2p. On the column, row 1 heading a group is the column-top END row of Table 6.4: min(2m + 0.625e + 0.5p, e1 + 0.5p) and min(πm + p, 2e1 + p). On the end plate, row 2 heading a group is the first row below the flange of Table 6.6: 0.5p + αm − (2m + 0.625e) and πm + p, with the same α as in the last step. Modes 1 and 2 use ℓeff,1 = min(Σℓeff,nc, Σℓeff,cp) and ℓeff,2 = Σℓeff,nc, mode 3 all the bolts of the group, and the web in tension over ℓeff,1 (the column web with ω, the rafter web) caps the group.
9. The compression zone EN 1993-1-8 6.2.6.2, 6.2.6.7
The haunch flange pushes on the column web. The web spreads the load over beff,c,wc; ω allows for the shear in the same web (β = 1 for a one-sided joint, Table 5.4); kwc = 1 because the page does not know the column stress (the calculator flags this). On the rafter side, the haunched section is deeper than 600 mm, so 6.2.6.7(1) limits the web to 20 % of the resistance: the flange force alone, 12.7 × 190 × 355, divided by 0.8. With the rafter cutting the haunch flange is 190 × 12.7 mm (the engine's rafter table, b = 190 mm).
10. Moment resistance EN 1993-1-8 6.2.7.2; SCI P398 Step 4 (force line)
The engine shares the moment among the tension rows in proportion to their distance from the centre of compression (a linear distribution): row r carries Fr = M hr / Σh², and the compression is ΣFr. This is safer than the plastic distribution of 6.2.7.2, in which each row may take its full resistance from the top down. Mj,Rd is then the moment at which the first row, row group, the compression zone or the column web panel reaches its resistance.
11. Forces at the design moment EN 1993-1-8 6.2.7.2
At MEd = 220 kNm the rows carry their share of the moment, and their sum is the force in the compression zone, in the column web panel and in each flange weld.
12. The flange welds EN 1993-1-8 4.5.3 (directional method)
Each flange is welded to the plate with two 8 mm fillets across its 190 mm width (throat a = 0.7 × 8 = 5.6 mm, L = 2 × 190 = 380 mm), and each must carry the flange force Fc,Ed. A force at right angles to the weld gives σ⊥ = τ⊥ = F / (a L √2) on the throat; the directional method asks √(σ⊥² + 3τ⊥²) ≤ fu / (βw γM2) and σ⊥ ≤ 0.9 fu / γM2, with fu = 490 MPa and βw = 0.9 for S355.
13. Vertical shear EN 1993-1-8 Table 3.4; SCI P398 shear-row rule
The shear row takes the full bolt resistance; the five rows working in tension are given only 0.28 Fv,Rd per bolt (the SCI P398 rule the engine uses). Bearing on the 20 mm plate at the shear row (end distance 35 mm) is checked per bolt and is larger than Fv,Rd.
14. The other checks EN 1993-1-8 6.2.6.7(2); EN 1993-1-5 6.2, 7.2; EN 1993-1-8 4.5.3.3, Table 3.3
These are quoted from the calculator, not worked here. The haunch rules of 6.2.6.7(2): the same steel grade, the flange and web no smaller than the rafter's (a cutting), and the flange at no more than 45° to the rafter: atan(300/500) = 31.0°. The rafter web at the haunch toe takes the vertical part of the haunch flange force (EN 1993-1-5 6.2), and the toe section is checked for its bending and shear (7.2), with M at the toe = 220 − 120 × 0.5 = 160 kNm. The haunch welds, the bolt spacing of Table 3.3 and block tearing all pass. The full-strength web weld (SCI P398 Step 7) is shown at 88 %: a rule for sizing the weld, not an applied force, so it is not in the utilisation.
15. The calculator's answer
The calculator, with the same inputs, gives Mj,Rd = 588.7 kNm (engine statix-endplate-engine stage 1 (app build 0.10.678, sha256 88db02ce1a40)) and PASS at 50.5 %, governed by the flange weld. The hand calculation gives the same numbers. Without the haunch the same plate and bolts give 329.6 kNm: the haunch multiplies the moment resistance by 1.79. Try a 400 mm haunch, or a deeper column, in the calculator.
Open the eaves haunch connection calculator
A worked example for learning, not a design. Check every value against the current code and your own project, and have the design checked and signed by a registered professional engineer.
Be first to use STATIX 3D.