A cold-formed lipped channel carries 15 kN of compression with 3 kNm of bending over 3 m. Here the Direct Strength Method of SANS 10162-2 is worked by hand for a C 200 × 75 × 20 × 2.0 in G450 steel. The hand calculation is checked against the STATIX cold-formed member calculator.

1. The problem

InputValue
Sectionlipped channel C 200 × 75 × 20 × 2.0 (library), D = 200, B = 75, lip 20, t = 2.0 mm, corner radius not given (0)
SteelG450, f_y = 450 MPa, E = 200 000 MPa
LengthsL_x = L_y = L_z = 3.0 m, K = 1.0; compression flange restrained for bending
Design actionsN* = 15 kN (compression), M_x* = 3 kNm, M_y* = 0, V* = 5 kN; C_mx = 1.0

2. The method SANS 10162-2 Section 7 (Direct Strength Method)

SANS 10162-2:2011 adopts AS/NZS 4600:2005. Its Direct Strength Method (DSM) needs three elastic buckling loads of the whole section: local (the flat plates ripple over short waves), distortional (the flange and lip rotate about the web junction) and global (the member buckles as a whole). Each is turned into a strength by its own curve, and the lowest strength governs. The calculator works on the centreline of the section with square corners: the library row of this section gives no corner radius, so ri = 0.

D = 200B = 75lip 20t = 2.0 mmcentroidshear centrex₀ = 54.4 mmx̄ = 21.2 mm

3. Section properties on the centreline square corners

The centreline lengths are the overall sizes less the thickness: web h = D − t, flange bf = B − t, lip dl = Lp − t/2. Thin-walled sums: each straight piece is a line of thickness t. x̄ is the centroid measured from the web centreline.

h = 200 − 2 = 198 mm, b_f = 75 − 2 = 73 mm, d_l = 20 − 1 = 19 mm A = t (h + 2 b_f + 2 d_l) = 2 × (198 + 2 × 73 + 2 × 19) = 764 mm² (library: 764 mm²) x̄ = (b_f² + 2 b_f d_l) / (h + 2 b_f + 2 d_l) = (73² + 2 × 73 × 19) / 382 = 21.212 mm I_x = t h³/12 + 2 b_f t (h/2)² + 2 [t d_l³/12 + d_l t (h/2 − d_l/2)²] = 1 293 732 + 2 861 892 + 611 065 = 4 766 689 mm⁴ (library: 4 767 000 mm⁴) I_y = h t x̄² + 2 [t b_f³/12 + b_f t (b_f/2 − x̄)²] + 2 d_l t (b_f − x̄)² = 178 180 + 197 919 + 203 831 = 579 931 mm⁴ J = t³ (h + 2 b_f + 2 d_l) / 3 = 2³ × 382 / 3 = 1018.67 mm⁴

4. Shear centre and warping constant thin-walled theory

A channel twists about its shear centre, which lies outside the web, on the side away from the flanges. For a lipped channel with square corners both the shear centre distance m (from the web centreline) and the warping constant Cw have closed forms in a = h, b = bf, c = dl (the calculator integrates the same thing along the centreline and gets the same numbers).

m = b t [3 a² b + c (6 a² − 8 c²)] / (12 I_x) = 73 × 2 × [3 × 198² × 73 + 19 × (6 × 198² − 8 × 19²)] / (12 × 4 766 689) = 33.182 mm x₀ = m + x̄ = 33.182 + 21.212 = 54.394 mm (centroid to shear centre) C_w = t a² b² / 12 × [2a³b + 3a²b² + 48c⁴ + 112bc³ + 8ac³ + 48abc² + 12a²c² + 12a²bc + 6a³c] / [6a²b + (a + 2c)³ − 24ac²] = 4 615 385 301 mm⁶ r_x = √(I_x/A) = 78.988 mm, r_y = √(I_y/A) = 27.551 mm r₀₁ = √(r_x² + r_y² + x₀²) = √(78.988² + 27.551² + 54.394²) = 99.784 mm, β = 1 − (x₀/r₀₁)² = 0.7028

5. Local buckling element method; used in 7.2.1 and 7.2.2

The calculator takes each flat element on its own with simply supported edges: the plate buckling stress k π² E / (12 (1 − ν²)) (t/b)², with k = 4 for the web and the flange in compression, 0.43 for the lip, and 23.9 for the web in bending. The lowest element governs. This leaves out the interaction between the elements; a finite strip analysis (CUFSM) gives the value for the whole section, and the calculator's advanced inputs take it instead. E = 200 000 MPa, ν = 0.3.

π² E / (12 (1 − ν²)) = 180 762 MPa compression: web 4 × 180 762 × (2/198)² = 73.77 MPa, flange 4 × 180 762 × (2/73)² = 542.7 MPa, lip 0.43 × 180 762 × (2/19)² = 861.2 MPa → f_ol = 73.773 MPa (web), N_ol = A f_ol = 764 × 73.773 / 1000 = 56.36 kN bending: web 23.9 × 180 762 × (2/198)² = 440.79 MPa (flange 542.7 MPa) → f_ol = 440.79 MPa (web), M_ol = S_f f_ol (in the bending step)

6. Distortional buckling SANS 10162-2 Appendix D (D2, D3)

This step is NOT worked by hand: the distortional buckling stresses are taken from the calculator. They come from the Lau and Hancock closed form of Appendix D, a long chain of flange-and-lip properties, a half-wavelength and a rotational spring kφ that is worked twice. The compression and bending cases have their own half-wavelength and spring. The calculator itself notes that its compression branch has not yet been confirmed against an independent finite strip run. Every step after this one is worked by hand.

compression: f_od = 217.44 MPa (half-wavelength 723.5 mm), N_od = 764 × 217.44 / 1000 = 166.13 kN bending: f_od = 385.57 MPa

7. Global buckling in compression SANS 10162-2 3.4.2, 3.4.3

A singly symmetric channel buckles either in flexure about its minor axis y, or in flexure about x coupled with twist (flexural-torsional). All lengths are 3.0 m with K = 1. G = 80 000 MPa.

f_ox = π² E / (L/r_x)² = π² × 200 000 / (3000/78.988)² = 1368.4 MPa f_oy = π² E / (L/r_y)² = π² × 200 000 / (3000/27.551)² = 166.48 MPa f_oz = (G J + π² E C_w / L²) / (A r₀₁²) = (80 000 × 1018.67 + π² × 200 000 × 4 615 385 301 / 3000²) / (764 × 99.784²) = 143.78 MPa f_oxz = [(f_ox + f_oz) − √((f_ox + f_oz)² − 4 β f_ox f_oz)] / (2β) = 139.10 MPa f_oc = min(f_oy, f_oxz) = 139.10 MPa (flexural-torsional), N_oc = 764 × 139.10 / 1000 = 106.28 kN

8. Compression capacity SANS 10162-2 7.1.1, 7.2.1

The DSM column curves: global first (Nce), then local buckling acting on the global strength (Ncl), and distortional on the squash load (Ncd). The full φc = 0.85 applies because the section lies inside the pre-qualified limits (checked below with the overall dimensions).

N_y = A f_y = 764 × 450 / 1000 = 343.8 kN global: λ_c = √(N_y/N_oc) = √(343.8/106.28) = 1.7986 > 1.5 → N_ce = 0.877 N_oc = 93.20 kN local: λ_l = √(N_ce/N_ol) = √(93.20/56.36) = 1.2859 > 0.776 N_cl = [1 − 0.15 (N_ol/N_ce)^0.4] (N_ol/N_ce)^0.4 N_ce = (1 − 0.15 × 0.8178) × 0.8178 × 93.20 = 66.87 kN distort: λ_d = √(N_y/N_od) = √(343.8/166.13) = 1.4386 > 0.561 N_cd = [1 − 0.25 (N_od/N_y)^0.6] (N_od/N_y)^0.6 N_y = (1 − 0.25 × 0.6464) × 0.6464 × 343.8 = 186.31 kN N_c = min(93.20, 66.87, 186.31) = 66.87 kN (local governs) Table 7.1.1 (lipped channel, compression): d/t = 100 < 472, b/t = 37.5 < 159, 4 ≤ d1/t = 10 ≤ 33, 0.7 ≤ d/b = 2.67 ≤ 5.0, 0.05 ≤ d1/b = 0.267 ≤ 0.41, E/f_y = 444 > 340 Table 7.1.2 (channel, bending): d/t = 100 < 321, b/t = 37.5 < 75, d1/t = 10 ≤ 34, 1.5 ≤ d/b = 2.67 ≤ 17, d1/b = 0.267 ≤ 0.70, E/f_y = 444 > 421 → pre-qualified: φ_c = 0.85, φ_b = 0.90 φ_c N_c = 0.85 × 66.87 = 56.84 kN ≥ N* = 15 kN OK, 27 %

9. Bending capacity, major axis SANS 10162-2 7.2.2

The page ticks "flange restrained": the compression flange is held along its length (by sheeting, for example), so there is no lateral-torsional buckling and Mbe = My. The calculator takes the section modulus as the centreline Ix over half the overall depth.

S_f = I_x / (D/2) = 4 766 689 / 100 = 47 667 mm³, M_y = S_f f_y = 47 667 × 450 / 10⁶ = 21.450 kNm = M_be local: M_ol = S_f f_ol = 47 667 × 440.79 / 10⁶ = 21.011 kNm λ_l = √(M_be/M_ol) = √(21.450/21.011) = 1.0104 > 0.776 M_bl = [1 − 0.15 (M_ol/M_be)^0.4] (M_ol/M_be)^0.4 M_be = (1 − 0.15 × 0.9918) × 0.9918 × 21.450 = 18.109 kNm distort: M_od = S_f f_od = 47 667 × 385.57 / 10⁶ = 18.379 kNm λ_d = √(M_y/M_od) = √(21.450/18.379) = 1.0803 > 0.673 M_bd = [1 − 0.22 (M_od/M_y)^0.5] (M_od/M_y)^0.5 M_y = (1 − 0.22 × 0.9256) × 0.9256 × 21.450 = 15.812 kNm M_b = min(21.450, 18.109, 15.812) = 15.812 kNm (distortional governs) φ_b M_bx = 0.90 × 15.812 = 14.23 kNm ≥ M_x* = 3 kNm OK, 22 %

10. Shear capacity SANS 10162-2 3.3.4

The flat web depth carries the shear. The unstiffened web buckles in shear with kv = 5.34; with hw/t = 98 it is slender, so the elastic shear buckling load governs.

h_w = D − 2t = 196 mm, A_w = 196 × 2 = 392 mm² V_y = 0.6 f_y A_w = 0.6 × 450 × 392 / 1000 = 105.84 kN V_cr = A_w k_v π² E / (12 (1 − ν²) (h_w/t)²) = 392 × 5.34 × 180 762 / 98² / 1000 = 39.399 kN λ_v = √(V_y/V_cr) = 1.6390 > 1.227 → V_v = V_cr = 39.399 kN φ_v V_v = 0.90 × 39.399 = 35.46 kN ≥ V* = 5 kN OK, 15 %

11. Combined actions SANS 10162-2 3.3.5, 3.5.1

Bending with shear uses the circular interaction of 3.3.5. For compression with bending, N*/φcNc is above 0.15, so 3.5.1 asks for two checks: the member, with the moment amplified by 1/αn (Cmx = 1.0, the page default), and the section, with the section capacity Ns (local and distortional only, no member buckling).

3.3.5: (M*/φ_b M_bx)² + (V*/φ_v V_v)² = (3/14.231)² + (5/35.459)² = 0.064 ≤ 1 OK N*/φ_c N_c = 15 / 56.839 = 0.2639 > 0.15 N_ex = π² E I_x / L² = π² × 200 000 × 4 766 689 / 3000² / 1000 = 1045.5 kN, α_nx = 1 − 15/1045.5 = 0.9857 eq (a): 0.2639 + 1.0 × 3 / (14.231 × 0.9857) = 0.478 ≤ 1 OK N_s: λ_l = √(N_y/N_ol) = 2.4698 → N_cl = (1 − 0.15 × 0.4851) × 0.4851 × 343.8 = 154.66 kN; N_s = min(154.66, N_cd 186.31) = 154.66 kN eq (b): 15 / (0.85 × 154.66) + 3 / 14.231 = 0.325 ≤ 1 OK

12. The calculator's answer

The calculator, with the same inputs, gives φcNc = 56.8 kN (local governs), φbMbx = 14.23 kNm (distortional governs) and φvVv = 35.5 kN (engine cold-formed-engine.js v1). The highest utilisation is 0.478, the member check eq (a) of 3.5.1, and the verdict is PASS. The hand calculation gives the same numbers. Untick "flange restrained" in the calculator and lateral-torsional buckling over Lb = 3 m comes in.

hand: φN_c = 56.84 kN, φM_bx = 14.231 kNm, φV_v = 35.46 kN, eq (a) = 0.4778 calculator: φN_c = 56.84 kN, φM_bx = 14.231 kNm, φV_v = 35.46 kN, eq (a) = 0.4778 (PASS)
Run this example yourselfOpen the STATIX cold-formed member calculator. These are the calculator's default inputs (the library section C 200x75x20x2.0), so it opens on this example. Change any value and the result updates, with every check and a calc sheet.
Open the cold-formed member calculator

A worked example for learning, not a design. Check every value against the current code and your own project, and have the design checked and signed by a registered professional engineer.

Early access

Be first to use STATIX 3D.

STATIX 3D is still being built. Join the early-access list and we will tell you when it is ready for testing. One confirmation now, one message then.

Get early access