Cold-formed lipped channel to SANS 10162-2
A cold-formed lipped channel carries 15 kN of compression with 3 kNm of bending over 3 m. Here the Direct Strength Method of SANS 10162-2 is worked by hand for a C 200 × 75 × 20 × 2.0 in G450 steel. The hand calculation is checked against the STATIX cold-formed member calculator.
1. The problem
| Input | Value |
|---|---|
| Section | lipped channel C 200 × 75 × 20 × 2.0 (library), D = 200, B = 75, lip 20, t = 2.0 mm, corner radius not given (0) |
| Steel | G450, f_y = 450 MPa, E = 200 000 MPa |
| Lengths | L_x = L_y = L_z = 3.0 m, K = 1.0; compression flange restrained for bending |
| Design actions | N* = 15 kN (compression), M_x* = 3 kNm, M_y* = 0, V* = 5 kN; C_mx = 1.0 |
2. The method SANS 10162-2 Section 7 (Direct Strength Method)
SANS 10162-2:2011 adopts AS/NZS 4600:2005. Its Direct Strength Method (DSM) needs three elastic buckling loads of the whole section: local (the flat plates ripple over short waves), distortional (the flange and lip rotate about the web junction) and global (the member buckles as a whole). Each is turned into a strength by its own curve, and the lowest strength governs. The calculator works on the centreline of the section with square corners: the library row of this section gives no corner radius, so ri = 0.
3. Section properties on the centreline square corners
The centreline lengths are the overall sizes less the thickness: web h = D − t, flange bf = B − t, lip dl = Lp − t/2. Thin-walled sums: each straight piece is a line of thickness t. x̄ is the centroid measured from the web centreline.
4. Shear centre and warping constant thin-walled theory
A channel twists about its shear centre, which lies outside the web, on the side away from the flanges. For a lipped channel with square corners both the shear centre distance m (from the web centreline) and the warping constant Cw have closed forms in a = h, b = bf, c = dl (the calculator integrates the same thing along the centreline and gets the same numbers).
5. Local buckling element method; used in 7.2.1 and 7.2.2
The calculator takes each flat element on its own with simply supported edges: the plate buckling stress k π² E / (12 (1 − ν²)) (t/b)², with k = 4 for the web and the flange in compression, 0.43 for the lip, and 23.9 for the web in bending. The lowest element governs. This leaves out the interaction between the elements; a finite strip analysis (CUFSM) gives the value for the whole section, and the calculator's advanced inputs take it instead. E = 200 000 MPa, ν = 0.3.
6. Distortional buckling SANS 10162-2 Appendix D (D2, D3)
This step is NOT worked by hand: the distortional buckling stresses are taken from the calculator. They come from the Lau and Hancock closed form of Appendix D, a long chain of flange-and-lip properties, a half-wavelength and a rotational spring kφ that is worked twice. The compression and bending cases have their own half-wavelength and spring. The calculator itself notes that its compression branch has not yet been confirmed against an independent finite strip run. Every step after this one is worked by hand.
7. Global buckling in compression SANS 10162-2 3.4.2, 3.4.3
A singly symmetric channel buckles either in flexure about its minor axis y, or in flexure about x coupled with twist (flexural-torsional). All lengths are 3.0 m with K = 1. G = 80 000 MPa.
8. Compression capacity SANS 10162-2 7.1.1, 7.2.1
The DSM column curves: global first (Nce), then local buckling acting on the global strength (Ncl), and distortional on the squash load (Ncd). The full φc = 0.85 applies because the section lies inside the pre-qualified limits (checked below with the overall dimensions).
9. Bending capacity, major axis SANS 10162-2 7.2.2
The page ticks "flange restrained": the compression flange is held along its length (by sheeting, for example), so there is no lateral-torsional buckling and Mbe = My. The calculator takes the section modulus as the centreline Ix over half the overall depth.
10. Shear capacity SANS 10162-2 3.3.4
The flat web depth carries the shear. The unstiffened web buckles in shear with kv = 5.34; with hw/t = 98 it is slender, so the elastic shear buckling load governs.
11. Combined actions SANS 10162-2 3.3.5, 3.5.1
Bending with shear uses the circular interaction of 3.3.5. For compression with bending, N*/φcNc is above 0.15, so 3.5.1 asks for two checks: the member, with the moment amplified by 1/αn (Cmx = 1.0, the page default), and the section, with the section capacity Ns (local and distortional only, no member buckling).
12. The calculator's answer
The calculator, with the same inputs, gives φcNc = 56.8 kN (local governs), φbMbx = 14.23 kNm (distortional governs) and φvVv = 35.5 kN (engine cold-formed-engine.js v1). The highest utilisation is 0.478, the member check eq (a) of 3.5.1, and the verdict is PASS. The hand calculation gives the same numbers. Untick "flange restrained" in the calculator and lateral-torsional buckling over Lb = 3 m comes in.
Open the cold-formed member calculator
A worked example for learning, not a design. Check every value against the current code and your own project, and have the design checked and signed by a registered professional engineer.
Be first to use STATIX 3D.
STATIX 3D is still being built. Join the early-access list and we will tell you when it is ready for testing. One confirmation now, one message then.