Water storage tank to EN 1992-3 and SANS 10252-1
A rectangular reinforced concrete tank holds 3.2 m of water. Its walls bend both ways under the water and pull in tension as a ring; the crack width must stay small enough for the tank to stay tight; early-age heat and shrinkage crack a wall held at its base; the roof slab spans between the walls; and the tank must meet the water-supply rules of SANS 10252-1. Every number below comes from the STATIX water storage tank calculator with the values in step 1.
1. The problem
| Input | Value |
|---|---|
| Shape, inside size | rectangular, 6 m x 4 m |
| Inside height H | 3.5 m |
| Walls / floor / roof slab | 300 / 300 / 200 mm |
| Top water level (design) / lowest operating level | 3.2 m / 0.3 m |
| Ground water | none |
| Design route | EN 1992-1-1 + EN 1992-3, tightness class 1 |
| Concrete fck / steel fyk | 30 / 500 MPa |
| Cover | 40 mm (given for the exposure) |
| Early-age temperature drop T1 | 20 °C (given: EN 1992-3 Annex M) |
| Seismic basis | outside the SANS 10160-4 zones (given) |
| Required usable capacity | 60 kL (the local authority) |
| SANS 10252-1 items | ventilated, drainage, float valve, access 600 mm, drinking water, sampling tap 100 mm, inlet 40 mm, overflow h1 100 / h2 75 mm, warning pipe 25 mm at 30 mm |
The calculator also needs the values in the table it fills from its template (soil, roof loads and the rest). It lists each one as a value to confirm: if you leave them as they are, a passing tank reads REVIEW, not PASS (step 9).
2. Water pressure
The water pushes on the walls with a pressure that grows in a straight line with depth. At the base of the wall:
3. Horizontal bending and ring tension in the walls
A wall held by the other walls at its ends and by the floor at its base bends both ways. Horizontally it also carries the tension that holds the opposite walls together. The calculator uses the strip method (named on the calc sheet). On the inside face, at the corners:
The outside face (mid-wall under the water): M = 89.3 kNm/m, 1 239 mm²/m, 39 %. Vertically the wall is a cantilever from the floor: 28.3 kNm/m inside (18 %), and the shear at the base, 0.213 MPa against vRd,c 0.511 MPa, needs no links (42 %).
4. Crack width: the tank must stay tight
For tightness class 1, EN 1992-3 7.3.1 limits the crack width by the ratio of the water depth to the wall thickness, hD/h = 3.2/0.3 = 10.7:
This is the governing check. It is why the bars are Y20 @ 100, not the Y16 @ 150 that strength needs. The other faces: 0.148 (86 %), vertical 0.150 inside (87 %, Y16 @ 125) and 0.156 outside (91 %, Y10 @ 100).
5. Early-age heat and shrinkage
A wall cast on an older floor is held at its base. As it cools after casting and as it shrinks, the restraint pulls it in tension and it cracks right through. EN 1992-3 Annex M:
T1 depends on the cement, the wall thickness and the formwork. The calculator does not guess it: without T1 this row reads NOT CHECKED.
6. Floor at the wall joint
With no ground water the floor bears on the ground. The wall base moment carries on into the floor, top face at the joint:
7. Roof slab
The 200 mm roof slab spans one way over the short span, simply supported on the walls:
8. The water-supply rules (SANS 10252-1)
A storage tank for drinking water must be covered and ventilated, drained, controlled by a float valve and open for inspection, with the overflow and warning pipe at set heights. The usable capacity is between the operating levels:
9. Result, and what REVIEW means
With every value above given, the tank reads PASS; the governing row is the horizontal crack width on the inside face (93 %). Give only the early-age temperature drop, the capacity and the seismic basis, and leave the rest as the calculator fills it: the same tank reads REVIEW. The calculator names the values it took from its template (the 40 mm cover for the exposure, ventilation, the capacity requirement and the other SANS 10252-1 items) and asks you to confirm them. REVIEW is never shown as PASS.
10. Do it in STATIX
Open the water storage tank calculator, type the values in step 1 and compare the rows with the steps above. Sign in to see every check, step by step, on the calc sheet.